Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
23 Cards in this Set
- Front
- Back
which type of wrench should you use to tighten an internal wrenching nut |
Allen |
|
Accident prevention involving hand tools is a matter of |
Proper instruction training and safety practices |
|
Which type of torque wrench is most commonly used |
Break away |
|
Which pair tool would you use to remove a multitude of access door screws |
Impact wrench |
|
Before using a bench grinder you should check the Integrity of the grinding wheels by |
Tapping them with a plastic mallet |
|
Which tool would you use to repair a fuel cell fitting flange |
Pneumatic buffer |
|
Which type of buffing attachment would you use on bladder cells and flange |
Stone |
|
The ratio of output pressure to input pressure of a two-part sealant high pressure injection gun is |
50 - 1 |
|
After you are finished using the sealant filleting gun what must be done to the gun |
Clean residual sealant |
|
The one part sealant injection gun is used to inject one part sealant into |
Channels under the wings skin |
|
What is the pressure ratio for the high pressure injection gun |
70 - 1 |
|
If you operate a Pneumatic power tool higher than the specified air pressure |
It could explode |
|
When a water manometer is used on a fuel tank you should |
Unplug the negative pressure connection when the fuel tank is getting a positive test |
|
Prior to operating the photo ionization detector what is the first item you should check |
Inspection date |
|
The Model T 477 W bonding meter is designed to measure |
Resistance |
|
What button is pressed to turn on the T 477 W bonding meter display and change the meter range |
Test |
|
What fuel maintenance support equipment item provides both low and high air pressure systems |
Mc-1a |
|
What fuel maintenance support equipment item is designed to operate pneumatic tools at a maximum air pressure 200 pounds per square inch |
MC-2A |
|
Which is a feature of the MC - 7 air compressor |
Capable of delivering high-volume of air |
|
The operating temperature range of the HDU-13 M heater is |
40-200 |
|
What heater is not explosion-proof in must be kept outside the fuel repair area |
H dash 1 |
|
What system is installed and Hangers that are used for curing sealant and purging |
H - 1 |
|
What equipment item provides air for Rapid purging of fuel tanks and for breathing |
climate control unit |