Water supply to house minimum size |
3/4" |
|
Showers used for other than safety reason shall be equipped with flow control devices to limit total flow to a max of ___ GPM per shower head |
2.5 GPM |
|
Lav faucets in public toilet facilities limit water to a max of ____ gpm unless a metering faucet is provided that limits delivery to a maximum of ____ GPM per metering cycle |
.5 GPM .25 GPM |
|
Max temp of public restroom faucet |
110° |
|
Max temp in domestic hot water in residential buildings shall not exceed _____°F |
130°F |
|
Flushometer toilets shall use max of ____Gallons per flush |
1.6 gallons |
|
Flushometer type urinals shall discharge a max of ____ per flush |
1 gallon |
|
All two-piece toilets shall be low consumption flushing ____ gallons per flush |
1.6 gallons |
|
The fixture water supply pipe shall be extended to within at least _____ inches of the point of connection to fixture |
30 inches |
|
Factor value X Demand Factor = ____ |
CV (pipe size) |
|
To boost water pressure in a home you use what? |
Booster pump and pressure tank |
|
All concealed tub/shower valves shall be _____ |
Provided with renewable seats |
|
Main controls on all water mains and branches, shall, when fully opened, have a cross sectional area ____________ in which they are installed |
Not less than the cross sectional area of pipe |
|
All potable water pressure tanks shall be provided with a vaccum relief valve at the top of the tank that will operate up to a max water pressure of ______ PSI and to a max water temp of ______°F |
200 PSI 200°F |
|
Potable water connections to a heating boiler shall be provided with an appropriate ______ to prevent cross connection |
Backflow preventer or air gap |
|
How is the size of the air gap measured? |
Lowest end of potable water outlet to flood level rim |
|
What is the minimum size air gap? |
Twice the effective opening of potable water outlet |
|
Vaccum breakers shall be installed with the critical level at _____ above flood level rim of fixture they serve |
Least 6" |