What type of Nitrogen is used on the NAN Cart?

Oil Free, Type 1, Class 2, Grade B

AG-750AO-OMM-000, WP 002 00

How pure must the Nitrogen be on the NAN Cart?

99.5%

AG-750AO-OMM-000, WP 002 00

What component controls the flow of Nitrogen from the manifold to the motor regulator and from the low pressure air connection to the motor regulator?

Motor Inlet Selector Valve

AG-750AO-OMM-000, WP 005 00

What is the range of the Motor Inlet Pressure Gauge?

0-200

AG-750AO-OMM-000, WP 005 00

What component controls the flow from the manifold to the suction side of the pump section?

Pump Inlet Valve

AG-750AO-OMM-000, WP 005 00

What component indicates pressure of Nitrogen in the service line for servicing high pressure aircraft systems?

Outlet High Pressure Gauge

AG-750AO-OMM-000, WP 005 00

What is the range of the Outlet High Pressure Gauge?

500-3500 (aircraft), 0-5000 (range)

AG-750AO-OMM-000, WP 005 00

What is the range of the Cylinder Pressure Gauge?

0-5000

AG-750AO-OMM-000, WP 005 00

What valve is used when recharging cylinders?

Manifold Bypass Valve

AG-750AO-OMM-000, WP 005 00

What component indicates Nitrogen pressure at the Regulator?

Manifold Pressure Gauge

AG-750AO-OMM-000, WP 005 00

What is the range of the Manifold Pressure Gauge?

0-5000

AG-750AO-OMM-000, WP 005 00

What is the range of the Outlet Low Pressure Gauge?

0-600 psi

AG-750AO-OMM-000, WP 005 00

What is the range for servicing aircraft systems with low pressure?

0-500 psi

AG-750AO-OMM-000, WP 005 00

What component controls the flow of Nitrogen from the manifold to the servicing line?

Manifold Shutoff Valve

AG-750AO-OMM-000, WP 005 00

In what direction should you rotate valves to open them on the Nitrogen Cart?

Counterclockwise

AG-750AO-OMM-000, WP 005 00

What component regulates the amount of pressure from the manifold to the servicing line in pounds per square inch?

Pressure Regulator

AG-750AO-OMM-000, WP 005 00

How far should you rotate the pressure regulator to increase pressure?

1/4 turn max clockwise

AG-750AO-OMM-000, WP 005 00

How far should you rotate the pressure regulator to decrease pressure?

1/4 turn max counterclockwise

AG-750AO-OMM-000, WP 005 00

What controls the flow of Nitrogen to the manifold for recharging the cylinders?

Recharge Valve and Connection

AG-750AO-OMM-000, WP 005 00

What could happen if you open more then one lever control valve at a time?

Equalization of pressure in cylinders

AG-750AO-OMM-000, WP 005 00

You should never use cylinders with pressure below what PSI?

200

AG-750AO-OMM-000, WP 005 00

What gauge should be observed when servicing is being done in the 500-3500 PSI range?

Outlet High Pressure Gauge

AG-750AO-OMM-000, WP 005 00

I'm what direction do you turn the pressure regulator to get a no flow connection?

Counterclockwise

AG-750AO-OMM-000, WP 005 00

When using external air, what indication should you get on the motor inlet pressure gauge?

117 PSI

AG-750AO-OMM-000, WP 005 00

The pump on the Nitrogen cart will automatically stop when manifold pressure reaches what PSI?

3500

AG-750AO-OMM-000, WP 005 00

What must pump drive pressure be at in order to obtain 3500 PSI?

117 on the motor inlet pressure gauge

AG-750AO-OMM-000, WP 005 00

For tire inflation servicing, what inflator kit assembly must you use?

M008348/1-1

AG-750AO-OMM-000, WP 005 00

What could result in possible damage to systems being serviced while using the NAN Cart?

Backflow of Contaminants

AG-750AO-OMM-000, WP 005 00

What kind of valve is used on the pressure regulator?

Positive Pressure Valve

AG-750AO-OMM-000, WP 005 00

When using the Nitrogen Cart in air drive the pump will automatically stop when pump pressure reaches what PSI?

3600