Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
33 Cards in this Set
- Front
- Back
Closed |
If inadvertantly BITE switch is actuated, what position does the apu/iso valve switch need to be in. |
|
30 sec. After the door open light goes out/after the n2 spools down completely |
How soon can a restart be attempted |
|
63+/-2 |
Normal Control N1 w load bleed valve closed |
|
N2 Always 100+/-1 |
N2 normal control for all loads |
|
78-91 |
N1 w load bleed valve open |
|
97 |
N1 load bleed valve ope , main bfn start |
|
75-100 |
N1 in standby control all loads |
|
100+/-4 |
N2 in standby all loads |
|
6 quarts |
Do not start APU oil quantity is below |
|
BAT/LOCKED |
Battery switch must be in the _____ position prior to APU start |
|
26vdc |
Battery voltage must be a minimum... |
|
2.5 quarts |
Shut down APU if oil quantity goes below... |
|
1,000, #2 |
There must be _____ lbs of fuel to start APU in the _____ tank |
|
0-1min on, 5 min off. 4 starts max in 20 min followed by 1 hour cool down |
Starter Duty Cycle |
|
4-5 |
If engine RPM indicator stops rising for any period of _____, terminate start |
|
85 |
Cockpit windows must be open if temperature exceeds ______ degrees |
|
Place APU GEN switch momentarily to reset |
If APU gen OFF light stays on... |
|
Shut down APU immediately |
If APU GEN off light stays on after reset... |
|
90seconds-2min |
Allow APU to operate w no load for____prior to Shut down |
|
60 seconds |
APU using BAT power light goes off ____after APU matter switch is placed in OFF position |
|
OFF, 50% N2 RPM |
APU oil pressure lo/temp hi light____ by... |
|
OFF, 95% N2 RPM |
APU gen OFF light _____ at.... |
|
ON, 95% N2 RPM |
APU Power Availbale light____ at... |
|
OFF, 95% RPM |
APU using bat power light _____ at... |
|
25%, 25, OFF |
If...N2 is not achieved in...seconds place APU in the...position |
|
Run, on, 30 |
After placing APU to the... position, APU USING BAT POWER should go...in... seconds |
|
45, 60 |
Acceleration time limit for APU start is... seconds warm... seconds cold. |
|
Immediately place APU MASTER POWER to the OFF position |
If APU OIL PRESS LO TEMP HI light does not turn on then turn off between 0-50% N2... |
|
Shut down APU immediately |
If APU FUEL PRESS LO light does not go out, or comes on during operation... |
|
Shut down APU immediately |
IF APU OIL PRESS LOW TEMP HI light comes on above 95% N2... |
|
Shut down APU immediately |
If APU USING BAT POWER light remains on above 95% N2... |
|
Shut down APU immediately |
If APU door closes during APU operation... |
|
585 Celsius |
APU temp limit is...degrees... |