What class of fire involves electrical current
class charlie
what class of fire involves liquids
class bravo
high concentration of __ are breathing hazards and require an OBA
CO2
what extinguishing agent has no cooling effect but breaks up the combustion chain
pkp
prior to hot work, the permit is serialized by the __ before it is posted
fire Marshall
what is the first step when communications are lost during hot work
cease hot work
what is a safe distance for all combustibles prior to hot work
35 ft or more
who does the fire watch muster with
Fire Marshall or edo
what are the 3 material conditions of readiness
x ray, yoke, zebra
closed only to prevent the spread of damage during CBR attack
circle William
set when the ship is in no danger of attack or natural hazard, well protected harbor or home port fair weather and working hours
x ray
set during general quarters or when directed by c.o.
zebra
what is a flat block placed under end of shore to distribute pressure
shoal
what kits are kept in repair lockers and are constructed/packed to fit through the smallest scuttle
pipe patching kits
shoring kits
plugging kits
electrician kit
what is a portable beam that provides support against, beneath or above damaged areas to prevent additional sagging, bolging and fatigue
a shore
what kid includes a flashlight, tape measure, pen, tool belt, adjustable, dog wrench, electrician gloves, electric shell gloves, fireman gloves, message blanks
investigator kit
what identifies access to / from battle stations, compartments containing equipment that require periodic checks, fittings that must be opened for ammo transfer
circle x ray / circle yoke
duplicates will be labeled and placed on each entrance
compartment check of list (CCOL)
what prevents the spread of contaminants via air by natural/ forced ventilation
circle William
what is annotated in nstm 505
markings
what is the lowest temperature which a flammable material will emit vapors that ignite when flame/ spark is applied
flash point
the temp at which fuel will continue to burn after ignition, lower than flash point
automatic ignition
01-MCN-76
what marking system is this? where is it found? what are the diff. sections?
manual valve/ marking system
01-shaft/plant #
MCN-system designation
76-individual valve #
what is the lowest temp which flammable material must be heated to give off vapors that will ignite without application of spark or flame
fire point
this kit is equipted with CBR signs, unexploded mutation signs, black China marker, message blanks, timer, white chalk and scissors
CBR monitoring kit
the plugging, shoring material and pipe patching kit all have in common
all have wedges
this kit is used to ensure no further damage occurs outside boundaries of existing casualties. they operate in pairs and report to repair locker
investigator kit
shoring kits include what 6 items
shore
wedge
shoal
strong back
steel shore
lumber
the viewing screen has indicator lights located on the __ side. how many are there, what color
left, 2 red, 2 lights
the automatic lense of a NFTI is made of what
germanium, grayish white chemical element: part of carbon family
__ mode is used for a detailed assesment of thesituation, it can detect a difference of __
chop, 4
how long does 10 AA batteries last in a NFTI
60-90 min
prevent flow of contaminates via fluid
William
__ __ fittings can be ordered open to provide comfort and healthful conditions for crew during prolonged periods of general quarters
circle zebra
provides maximum water tight integrity
zebra
what are the 5 special DC classifications
William, circle William, circle x ray / yoke, cielce zebra, dog zebra
AFFF is used in what type of rooms
MMR / AMR / PUMP ROOMS / FUEL SORE ROOMS
what does NFTI stand for
naval firefighters thermal imager
what class of fire is AFFF the primary extinguishment
class bravo
the nfti is used by who. can it be used through class or metal
attack team leader
hose team leader
no
when establishing communications, fire watches are posted on all aides of the hot work. they communicate by __
speaking, radios, visual signs, messengers, sound powered telephone
when hot work is complete the firewatch must stay on station for _ minutes or _ to ensure nothing is smoldering
30 minutes or cool to touch (whichever is longer)
seeing or smelling excessive smoke and fumes is __. what do you do
abnormal
cease hot work and notify dcc, fire marshal, gfe/gfea, edo
once hot work is underway maintain a __ watch over the area. you must __ __
vigilant
maintains surveillance
used to cover vertical smoke at open hatch
smoke blankets, 14×14
the 3 communication paths for desmoking is
wifcom, spt, messenger
what are used to spread of lateral smoke at doorways and passageways, made of fiberglass material
smoke curtains
boundary information is plotted by __ and all __
DCC
all repair lockers
while import/ underway __ for the space or fitting is responsible for preparing their area IAW current condition
division responsible
what material condition is checked at the end of day underway
yoke
during general quarters the __ has responsibility for the area of the repair locker
repair party
material condition __ is always set, manned and check twice a day
x ray
the box fan plugs into a __ outlet and has a __ ft cord
115
50
T/F
the box fan may be used for both +/- ventilation
true
T/F
if the tamper seal on a box fan is broke. or removed on the motor, it is okay to use the fan in an explosive atmosphere
false
desmoking evolutions must be preformed after what
the fire has been extinguished
the automatic iris closes if pointed at spots greater than
140°
how long should the NFTI be left to warm up
1 minute
T/F
the NFTI has the connection for an external monitor, which can be reloaded
true
the __ has a magnifying lens that displays a 0-45', but the best image is __
viewing screen
26'-45'
who communicates with the de smoking team and determines whether to use +/- procedures
On Scene Leader
DCA
ships __ lists both primary and secondary smoke boundaries
1st doctrine
the __ and __ decide what type of desmoking equipment is required for space
Repair Party Leader
On Scene Leader
with smoke curtain clamps must maintain continuous contact with __ and or __
door
hatch knife edge
what is opened during all material conditions and secured only to control damage or casualties and to effect repairs
William
who usually grants permission tobalter a previously set material condition or readiness
Damage Control Assistant
these fittings must be guarded when opened, so that they maybe closed immediately when necessary
circle zebra
the __ provides the location and purpose of all classified closures and fittings and other DC and firefighting system and equipment for that space
Compartment Check Off List
when operating a NFTI, depress the __ button on the __ to turn on. the image will appear within __ sec
red
voltage stabilizer
4-5
how do you change the operating mode on the NFTI
blue bottom on front
one light on the battery indicator means what
change batteries
the __ the image, the better the image
hotter (DONT POINT TOWARDS SUN )
to decrease the risk of electrical shock on a ram fan you should ensure what components
ground strap is grounded to a steel structure
the box fan removes __ ft2 m
3200
the ram fan is a __ portable blower
high capacity volume
a med. capacity portable desmoking fan is known as
box fan
every kit inventoried IAW PMS and has an inventory list attached. what is the inventory list reffered to as
AEL Allowance Equipage List
what are the 2 damage control kits
CBR monitoring kit
investigator kit
water may be used on class c fores if it is how many feet away
4
__ is used for rapid assessment of situation and shows changes in temp of the scene
pan mode of operation on the NFTI
what equipment can be used to see the seat of a fire, locate compartbent access and guide rescuers to injured/ trapped personnel
NFTI
is used to set and maintain fire boundaries band locate ignition sources during fire overhaul
NFTI
what is any operation that produces a temp of 400° or higher
hotwork
(welding,torch cutting,brazing,flame heating )
who issues a gas free certificate for entry / work or tests and inspections conducted
GFE/ GFEA
what are the 6 responsibilities for standing fire watch
-prior to hot work
-muster, obtain and inspect equip
-establish communications
-maintain surveillance
- inspect area
- inspect/ return equipment
who must be withkng 50ft of operations with an unobstructed view
fire watch
who do you contact under way if a fire occurs that you cannot extinguish? in port ?
underway- bridge or DCC
inport- ood
what do you do after completion of hot work on a fuel tank
vent area
during hot work if the fire agent does not work you must wait for
fire party
if there is an emergency / malfunction during hot work who inspects the space before resuming work
fire marshal
edc and gfe
what class of fire is identified by ashes left by organic material
class a
what extinguishing agent chemically inhibits the flame front
halon
the slow oxidation that turns into fast oxidation if heat is not dissipates and result in a fire
spontaneous combustion
what is a cooling agent
water
do not exceed __ psi pump discharge pressure while testing the __ valve or the pump may be damaged
250
relief
the discharge pressure should build up to __ psi or the pump will be running dry and not deliver fluid
15
the __ valve in the AFFF line to the re entry hose reel located on the DC deck must be open to charge the hose
cut out valve
the ball valve in the AFFF line to the re entry hose reel on the DC deck must be __ to charge that hose
open
a class d fire is what type of fire
combustible metals
magnesium, titanium, sodium, magnesium flares
what extinguisher is used to extinguish burning cooking oil and grease in galley fires
APC (Always Protect the Cook)
what must you know about class bravo fires before extinguishing it
the type of fuel involved
what class of fire should you never use water on
class b
in emergency, there is a __ and __ in the case of the battery cartridge
1.0
fuse
if activating AFFF system and pump fails to start, turn the switch on the motor controller to the __ position
local/run
T/F
the NFTI can not monitor the speed of fire
false
T/F
pushing the "on" button located at the AFFF position operating station starts on AFFF pump, mixes concentrate, and charges all hoses
true
what labke contains shaft/ plant # system designation and include valve #
manual valve marking system
what 2 types of bulkheads are found on ships
structural
non structural
what is known as frame 0 and labeled A,B,C forward and AA, BB, CC aft
forward perpendicular
what I'd lable contains color coded, numbered, lettered, symbol. also lowrsr number is a orgin and continues in intervals
shipboard piping system designation markings (ventilation system )
CCOL must be verified and signed off by whom
division officer
where is the damage control closure log kept
maintained in DCC
quarterdeck when maintained
what master copy of the CCOL is maintained by whom
DCA
what is a constantly maintained record of the status of damage control closures and fittings
damage control closure log
T/F
work continues if hydrogen sulfide odor is detected
false
when hydrogen sulfide is detected, discharge will report to whom
eoow, dca, OE appropriate authority
consists of transverse frame/ decks, decks run outboard from keel to turn of bilge, attatch transfer frame that extend up to main deck
athwart ship structures
2nd part of compartnment #, indicates foremost boundary of compartment. numbered consecutively stern to stern (fwd to aft )
frame number
what system is used by the navy for naming various structural parts of the ship
shipboard nomenclature
below the lowest complete deck and do not extend the length of the ship
platforms
18lb - 19ft (10 seconds)
27lb - 21 ft ( 11 seconds)
PKP
magnesium flares smothered with
sand
secure power and extinguish with CO2
class c
primary agent AFFF
class b
primary agent AFFF ( too much is hazardous )
class A
at 40 psi moves 100 cubic fr of air per minute with 15×10 trunk
ram fan
at 250 psi moves 2530 cubic ft per minute with 15×10 trunk
ram fan
4th part of compartment #, indicates what compartment is used for
compartment usuage
port
even
stbd
odd
secured during darken ship to prevent light from showing outside the ship
dog zebra
set and maintained at sea, import outside of normal working hours
yoke