Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
27 Cards in this Set
- Front
- Back
Control Rod operability reqs
|
Each control rod shall be OPERABLE in modes 1 & 2
|
|
One withdrawn control
rod stuck. |
-Verify stuck control
rod separation criteria are met - IMMEDIATELY -Disarm the associated (CRD) - 2 hrs |
|
Control Rod Scram Times reqs
|
a. No more than 12 OPERABLE control rods shall be "slow,"
in accordance with Table 3.1.4-1; and b. No more than 2 OPERABLE control rods that are "slow" shall occupy adjacent locations. Apllicable in modes 1&2 |
|
Control Rod Scram Accumulator reqs
|
Each control rod scram accumulator shall be OPERABLE.
-APPLICABILITY: MODES 1 and 2. |
|
Two or more accumulators
inoperable with reactor SDP > 900 psig. |
-Restore charging
water header pressure to >= 940 psig. - 20 min AND -Declare the associated control rod scram time "slow." - 1 hr OR -Declare the associated control rod inoperable.- 1 hr |
|
One or more control
rod scram accumulators inoperable with reactor SDP >= 900 psig. |
-Verify all control
rods associated with inoperable accumulators are fully inserted. - Immediately -Declare the associated control rod inoperable. - 1 hr |
|
Rod Pattern Control reqs
|
OPERABLE control rods shall comply with the requirements of
the analyzed rod position sequence. APPLICABILITY: MODES 1 and 2 with THERMAL POWER >= 10% RTP. |
|
Nine or more OPERABLE
control rods not in compliance with the analyzed rod position sequence. |
-Suspend withdrawal of
control rods. - Immediately AND -Place the reactor mode switch in the shutdown position. - 1 hr |
|
Standby Liquid Control (SLC) System reqs
|
Two SLC subsystems shall be OPERABLE.
APPLICABILITY: MODES 1, 2, and 3. |
|
Scram Discharge Volume (SDV) Vent and Drain Valves reqs
|
Each SDV vent and drain valve shall be OPERABLE.
APPLICABILITY: MODES 1 and 2. |
|
MINIMUM CRITICAL POWER RATIO (MCPR) reqs
|
All MCPRs shall be greater than or equal to the MCPR
operating limits specified in the COLR. APPLICABILITY: THERMAL POWER >= 25% RTP. |
|
Any MCPR not within
limits. |
Restore MCPR(s) to
within limits. - 2 hrs |
|
One or more Functions
with RPS trip capability not maintained. |
Restore RPS trip
capability. - 1 hr |
|
Intermediate Range
Monitors channel reqs a. Neutron Flux—High b. Inop |
a. 3 ch required per trip sys in mode 2
b. 3 ch required per trip sys in mode 2 |
|
Average Power Range
Monitors channel reqs a. Neutron Flux—High, Setdown b. Flow Biased Neutron Flux—High c. Fixed Neutron Flux-High d. Inop |
a. mode2/2 req ch per trip sys
b. mode1/2 req ch per trip sys c. mode1/2 req ch per trip sys d. mode1&2/2 req ch per trip sys |
|
Reactor Vessel Steam
Dome Pressure—High reqs |
modes 1&2 / 2 channels per trip sys
|
|
Reactor Vessel Water
Level—Low reqs |
modes 1&2 / 2 channels per trip sys
|
|
Main Steam Isolation
Valve—Closure reqs |
mode 1 / 8 channels per trip sys
|
|
Drywell Pressure—High reqs
|
modes 1&2 / 2 channels per trip sys
|
|
Turbine Stop
Valve-Closure reqs |
>= 38.5% / 4 channels per trip sys
|
|
Turbine Control Valve
Fast Closure, Trip Oil Pressure—Low reqs |
>= 38.5% / 2 channels per trip system
|
|
Turbine Condenser
Vacuum—Low reqs |
mode 1 / 2 channels per trip system
|
|
Reactor Mode Switch—
Shutdown Position reqs |
modes 1&2 / 1 channel per trip system
|
|
Source Range Instrument reqs
|
mode 2 - 3 required
mode 3, 4 - 2 required |
|
Three required SRMs
inoperable in MODE 2 with IRMs on Range 2 or below. |
Suspend control rod
withdrawal. - Immediately |
|
One or more required
SRMs inoperable in MODE 3 or 4. |
-Fully insert all insertable control rods. - 1 hr
AND -Place reactor mode switch in the shutdown position. - 1 hr |
|
One or more required
SRMs inoperable in MODE 5. |
-Suspend CORE ALTERATIONS except for control rod insertion. - Immediately
AND -Initiate action to fully insert all insertable control rods in core cells containing one or more fuel assemblies. - Immediately |