• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/49

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

49 Cards in this Set

  • Front
  • Back
The size of the hose refers to its ____ diameter.
inside
Intake hose that is used to transfer water from a pressurized water source to the pump intake is reffered to as ____ intake hose.
soft
The ____ intake hose is primarily used to draft water from a static source.
hard
To avoid mechanical damage to fire hose open and close nozzles, valves, and hydrants quickly. (true/false)
FALSE; open SLOWLY
A guideline for preventing hose liner dehydration is to roll dry hose in a straight roll for storage. (true/false)
TRUE
Between woven-jacket natrual fiber hose and rubber-jacket hose, which is more susceptible to mildew and mold through organic damage?
Woven-jacket natrual fiber hose
Fire hose that is exposed to petroleum products or paints would be an example of ____ damage.
Chemical
A recommended practice for preventing chemical damage is to scrub hose thoroughly and brush all traces of acid contacts with a solution of ____ and water.
Baking soda
Rinsing with clear water and using mild soap, if necessary, is the general washing method for hard-rubber booster hose, hard intake hose, and rubber-jacket collapsible hose. (true/false)
TRUE
_____-jacket hose must be thoroughly dried before being reloaded on an apparatus.
Woven-jacket hose
Couplings consist of a male coupling with external threads and a female coupling with internal cthreads are known as _______ couplings.
Threaded couplings
The portion of the coupling that serves as the point of attachment to the hose is called the _____.
Shank
Booster hose normally has couplings with double lugs. (true/false)
FALSE; booster hose has recesseed lugs
The majority of new threaded couplings have rounded ____ lugs.
Rocker
The special cut at the beginning of the thread on a hose coupling that provides positive identification of the first thread to eliminate cross-threading is referred to as?
The Higbee cut
All Storz couplings of the same size are identical and may be connected to each other. (true/false)
TRUE
The ___ gasket is used to make the connection watertight when female and male ends are connected on threaded couplings.
swivel
Water flows ___ appliances but ___ through tools.
through; NOT
The ___ valve is used to control the flow from a hydrant and has a baffle that is moved by a handle and screw arrangement.
gate valve
The valve used on large pump intakes and incorporates a flat baffle that turns 90 degrees is known as the _____ valve.
butterfly
The _____ valve is used in Siamese appliances to allow water to flow in one direction only.
Clapper
Water theif appliances are MOST often used in wildland firefighting operations. (true/false)
TRUE
A ___ refers to an adapter used to attach smaller hose to larger hose.
Reducer
What fitting provides support for intake or discharge hose at the pumping apparatus?
Elbow
Intake _____ are devices attached to the drafting end of a hard intake to keep debris from entering the fire pump.
strainers
The hose ____ prevents damage from hose being dragged over sharp corners
Hose roller
The hose tool used to stop the flow of water in a hoseline is referred to as a hose _____.
Hose clamp
A hose jacket is a hose tool that can be used to connect hose with mismatched or damaged screw-thread couplings. (true/false)
TRUE
The _____ wrench is used primarily to remove caps from fire hydrant outlets and to open fire hydrant valves.
Hydrant wrench
What type of wrench is used to primarily to tighten or loosen hose couplings?
Spanner wrench
When a hoseline is laid across a street or other area where it may be run over, a hose ___ is used.
Hose bridge
The ______ roll is the simplest of all hose rolls.
Straight roll
The ____ donut roll has the purpose of creating a compact roll that can be easily transported and carried for special applications such as high-rise operations.
Twin donut roll
The ___ hose load is an arrangement of fire hose in a hose bed or compartment in which the hose lies on edge with the folds adjacent to each other.
Accordion load
The ___ hose load is the easiest to load.
Flat load
The hose load best suited for large-diameter hose is the ___ load.
Flat load
The skid load finish is designed to provide an adequate amount of hose at the scene for initial attack. (true/false)
TRUE
The ___ finish is designed to facilitate making a hydrant connection.
Straight finish
The preconnected _____ load is adaptable for varying widths of hose beds and is often used in transverse beds.
Preconnected flat load
The hose load that is designed to be pulled and advanced by one person and has the primary advantage of being carried on the shoulder is referred to as the ___ load.
Minuteman
Booster lines are not appropriate for interior fire fighting operations and are mostly used in mop-up operations. (true/false)
TRUE
Supply hose with threaded couplings is usually loaded for a ____ lay
Forward lay
Which hose lay is hose laid from the water source to the fire?
Forward lay
The ____ lay is hose laid from the fire to the water source.
Reverse lay
When a hoselay is deployed by two pumpers, one making a forward lay and one making a reverse lay from the same point, it is known as a _____ lay.
Split lay
A guideline for advancing hose into a burning structure is to position the nozzle operator and all members of the hose team on altering sides of the hoseline. (true/false)
FALSE; position the nozzle operator and all members of the crew on the SAME side.
It is EASIER to advance _____ hoselines up stairways.
Uncharged
Whenever one firefighter is required to operate a small hose and nozzle, that hoseline should be straight for at least ____ feet behind the nozzle.
10 feet
Except for overhaul or for very small outdoor nuisance fires, the minimum number of firefighters required for handling any attack line is ____.
Two firefighters