Essential equipment for visual inspection (3) |
Torch screw driver mirror |
|
Equipment to remain in enclosure to aid inspection 1/4 stepladders.. |
And or scaffolding |
|
Equipment to remain in enclosure to aid inspection (2/4) Lig.. |
Lighting (a torch is used to supplement the lighting not replace it) |
|
Equipment to remain in enclosure to aid inspection (3/4) Vac.. |
Vacuum cleaner and other materials for minor cleaning |
|
Equipment to remain in enclosure to aid inspection (4/4) |
Buckets of water, sponges, wipes in airlock to aid preliminary decontamination |
|
Wet enclosures The area should be clean and dry (1/4) Ground... |
Groundwater seeping in - it may not be possible to get the area completely dry - consider use of pumps to prevent flooding - record information. |
|
Wet enclosures The area should be clean and dry (2/4) Leaking... |
Leaking pipe - sort the problem before a full certificate of reoccupation can be given. |
|
Wet enclosures The area should be clean and dry (1/4) If indent.... |
If identified prior to work - may require use of small enclosure to strip area so that leak can be repaired. |
|
Wet enclosures The area should be clean and dry (4/4) If occurs during work.. |
If occurs during work, area cleaned to enable plumber wearing suitable RPE / PPE to repair leak - then proceed with normal clearance when area dry. |
|
Sprayed sealent - should not be used before visual inspection (1/3) May be used... |
May be used to seal surfaces that may release non asbestos dust, but only analyst's discretion. |
|
Sprayed sealent - should not be used before visual inspection (2/3) If already applied... |
If already applied but still wet Stop the clearance. Issue failed certificate of reoccupation, indicating the reason. Sealant must be washed off and the area dried. |
|
Sprayed sealent - should not be used before visual inspection (3/3) if already dry... |
If already dry, issue failed certificate, consider way forward probably need to remove all dried sealant. |