Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
34 Cards in this Set
- Front
- Back
How many seconds must you wait between attempted APU starts? |
(maximum of 3 attempts, if 3rd attempt fails you must wait 55 minutes for start motor cool down) |
|
During a wing/APU fire on the ground, after you have verified a fire with the fire guard, your next step should be to_________.
|
Execute Emergency Shutdown |
|
If the APU system SBIT indicates a FAULT what will you see on the MFD WRA TEST status page?
|
component |
|
Electrical operating power for the APU engine system consists of ________. |
28 Volts Direct Current (VDC) |
|
What are the five EMERGENCY SHUTDOWN steps? (this question is go/no go)
|
2. APU STOP (as required) 3. Battery OFF 4. Egress (as required) 5. Ground Control ALERTED |
|
What components are driven by the MWGB during APU operations?
|
No. 3 Hydraulic pump, Oil Cooler Blower, Shaft Driven Compressor (SDC) |
|
________ shall not be selected for normal operation of the APU, damage to the ACFT may occur.
|
Emergency Run/Engage |
|
T/F. APU is limited to ground operations?
|
True |
|
During APU crank mode a time-out feature limits this operation to _________. |
30 seconds maximum |
|
T/F. The APU can only be started with external power applied?
|
False |
|
T/F. The APU system interfaces with the MWGB to provide electrical, hydraulic, pneumatic power?
|
True
|
|
Automatic shutdown protection is not provided for which situation?
|
Low fuel pressure. |
|
DISABLED if any wing/midwing panels are removed? |
True |
|
Fuel is supplied to the APU from the _______? |
RH feed tank. |
|
If the APU fails to start after 3 attempts, the APU start motor shall be allowed to cool for _____ minutes before next attempt. |
55 minutes minimum |
|
The APU is labeled, ______, ______, ______, ______, and ______. |
Run/Disengage Emergency Run/Engage Crank STOP |
|
T/F. A maintenance/VSLED download is required after every APU run?
|
False |
|
The #3 hydraulic system pressure should read between ____ - ____.
|
4600-5250 psi |
|
detection/protection is available? |
True |
|
When the APU is started which generator(s) is/are on-line?
|
Constant Frequency Generator (CFG) #1 |
|
The WFPS is located on which PDP? |
PDP 3 |
|
The first step of the APU checklist is ______. |
Aircraft safe for maintenance. |
|
During Run/Disengage mode the APU will preform the same function as Run/Engage mode except the ______. |
Clutch |
|
At what temperature must the APU clutch be preheated for 15-30 minutes? |
- 25 Degrees F and below |
|
Pertaining to APU operations, what is not checked for servicing at the GRDP?
|
CFG #1 |
|
When operating the APU in CRANK mode, how long will the APU motor?
|
30 seconds. |
|
The APU engage ASI will show up on the ______.
|
CDU |
|
What is the minimum battery voltage required for APU start? |
23.5 Volts |
|
What is the first step in the wing/APU fire checklist? |
Verify APU fire with fireguard
|
|
T/F. To prevent inadvertent actuation, the NAC CONT DSBL switches shall be selected to DSBL anytime nacelles are in flight ready?
|
True |
|
The APU ignition is initiated with two igniters which receive _______ volts from the ignition exciter.
|
5000 |
|
Once the APU has started, the fuel system will maintain what constant turbine speed?
|
98%-102% |
|
percent of the APU self-sustaining speed of 100%? |
50% |
|
What is the last step of a wing/APU fire on the ground?
|
Alert Ground Control |