What do you set the high pressure at?

Set @ 10cmH2O above peak Airway pressure

Alarm setting for minimum exhaled volume

Set 100 mL below exhaled tidal volume

What do you set the low pressure alarm at?

@10cmH2O below peak Airway pressure

What to can cause a low pressure alarm?

Leak in vent circuit


Insufficient flow

What can cause high pressure alarm?

Secretions, pneumo, ETT kink


Vent circuit obstruction

What causes low exhaled volume alarm?

Pt disconnect, low spontaneous VT