Disposal of sewage, or other liquid wastes, shall be by means of _____________________.
The drainage system of the building or premises
A drinking fountain installed outside shall be connected to an approved drainage system. T/F
True
A connection to the public sewer, or private sewer disposal system, is required for ___________________.
Buildings with plumbing fixtures
Roofs, inner courts, vent shafts, light wells, or similar areas having rainwater drains shall discharge to (a) ___________________________.
Outside of the building or to the gutter
Burred ends of all pipe and tubing shall be ______________________.
Reamed to the full bore of the pipe or tube
No plumbing system, drainage system, building sewer, private sewage disposal system, or parts thereof, shall be located in ___________________________.
Any lot other than the lot that is the site of the building served by such facilities.
Piping, fixtures, or equipment that are installed so that they interfere with normal operation and use of windows or doors shall be ________________.
Relocated to avoid interference
All design, construction, and workmanship shall be in conformity with ____________________.
Accepted engineering practices
When supporting horizontal piping 5-inches in diameter with hangers, a ____ inch diameter rod shall be used.
1/2
The building drain from the front of the building or structure and paralleling the same shall be at least ________________________.
On an interior lot (when driveway cannot be used)
All trenches deeper than the footing of any building or structure and paralleling the same shall be at least ____________________.
45 degrees therefrom
Cast-iron soil pipe, installed vertically, shall be supported at its base and ___________________.
Each floor, not to exceed 15 feet
Threaded pipe (I.P.S.), 3/4 inch, except for gas piping, installed horizontally shall be supported at approximately ___________________.
10-foot intervals
Piping in the ground shall be laid on _______________________.
A firm bed
PEX piping may be coupled together with shielded couplings. T/F
False
The type of acceptable joints for PEX shall be __________________.
Metal insert or metal compression
Copper tubing installed vertically shall be supported at each story or at maximum intervals of _____________________.
10 feet
Mechanical devices may be used to complete backfilling where covering above any piping is at least _____ inches.
12
Two-inch horizontal copper tubing drain pipe shall be supported at ____________________.
10 foot intervals
Horizontal hubless pipe shall be braced at not more than 40-foot intervals to prevent ________________________.
Horizontal movement
All piping, fixtures, and equipment shall be adequately supported in accordance with the ______________.
Code
Voids around piping passing through concrete floors on the ground shall be ____________________.
Sealed
All materials, fixtures, or devices used or entering into the construction of plumbing and drainage systems shall _______________________.
Conform to approved applicable standards.
The provisions of the code allow an alternate material or method of construction provided it is ______________________.
Approved by the Authority Having Jurisdiction as an alternate
I.P.S. is the abbreviation for ______________________.
Iron Pipe Size
Pipe joint material shall be insoluble in water, nontoxic, and applied ___________________.
On male threads only.
Wiped joints are permitted with ___________________.
Lead
Section 313.2 prohibits the direct embedment of hubless cast-iron in a concrete slab. T/F
True
Tub waste openings in framed construction shall be protected by ____________________.
Metal collars or screens
Surfaces to be joined by soldering or brazing shall be cleaned bright by ______________________.
Mechanical or manual means
Closet bends or stubs shall be cut off so as to present a smooth surface, even with the ____________________.
Top of closet ring
Solder and fluxes used in piping systems conveying potable water are prohibited when the lead content exceeds ______________________.
0.2 of 1 percent
Joints at the roof, around pipes, shall be made water tight by the use of _________________________.
Flashing material
The minimum wall thickness for threaded plastic pipe shall be ___________________.
Schedule 80
Wall-mounted water closets shall be securely bolted to ____________________.
A carrier fitting
It is permitted to drill and tap a vent pipe to connect an indirect waste pipe. T/F
False
Fixture connections between drainage pipes and water closets shall be made with _________________.
Flanges
All pipe, pipe fittings, traps, fixtures, materials , and devices used in plumbing systems shall be __________________________.
Approved by the Authority Having Jurisdiction
Sleeves shall be provided to protect all piping through _____________ and ______________.
Concrete; Masonry
In seismic zones 1 and 2, hubless cast-iron piping 5 inches or larger suspended in exposed locations over high traffic areas, and over four feet in length, shall be provided with support on both sided of the coupling. T/F
True
When installing __________________, the Authority Having Jurisdiction shall require evidence of the competency of the installers.
Medical gas piping
When brazing, the alloys shall have a melting temperature of at least ____________ degrees F.
1,000
Drain pipes subject to condensation over food storage in food-handling establishments shall be _______________________.
Thermally insulated
The section of the UPC that grants the Authority Having Jurisdiction the opportunity to require tests as proof of equivalency.
301.2.1
Test gauges shall not have a pressure range more than _______________ the test pressure.
Twice