Screws or bolts for securing floor-mounted fixtures shall be __________________.
Brass
Fixtures having concealed slip-joint connections shall be provided with ____________________.
A utility space or access panel
The overflow pipe from a fixture shall be connected on the ____________________.
House or inlet side of the fixture
Continuous wastes and fixtures tailpieces may be seamless drawn brass not less than __________.
1-1/2 inches OD
The diameter of a waste and overflow for a bathtub shall not be less than _________________________.
1-1/2 inches OD
No dry or chemical closet (toilet) shall be installed in any building used for human habitation unless first approved by the _________________________.
Health Officer
Tanks flushing more than one urinal shall be ________________.
Automatic in operation
Every water supply to a urinal shall be protected by an approved _____________________.
Vacuum Breaker
Trough urinals shall be _____________________.
Prohibited
To provide a watertight joint in the floor, shower drains and floor drains are required to be ______________________.
Suitably Flanged
With two noted exceptions, all shower compartments and receptors shall be capable of encompassing a __________________ diameter circle.
20-inch
The curb or threshold of a shower compartment may be eliminated __________________________.
To comply with the accessibility standards.
Shower pan linings may be constructed with ________________.
15 pounds asphalt felt
Joints in copper shower pan liners shall be ___________________.
Soldered or brazed
Drinking fountains shall not be installed in ___________________.
Public toilet rooms
Water closets set side by side shall be no closer than ________________________.
30 inches center to center
The minimum distance from a side wall or partition to the center of a urinal shall be _________ inches.
12
Manually controlled flushometer valves shall be used to flush more than ________________________.
One urinal
Automatically controlled flushometer valves may be substituted for ________________________.
Flush tanks
The joint of a wall-hung lavatory, where it is in contact with the wall, shall be _______________________.
Watertight
Galvanized sheet steel of not less than 16 U.S. gauge may be used to make dish-washing sinks for ___________________________.
Restaurants
Gutters in public shower rooms shall be sloped not less than _______________________.
2 percent
Wall-hung lavatories shall be supported by ______________________.
Metal hangers
The tailpiece diameter for lavatories and drinking fountains shall not be less than ___________________.
1-1/4 inches
A solidly formed sub-base is required so as to pitch shower pan linings to weep holes in the sub-drain with a fall of __________________.
1/4 inch per foot
Approved strainers having an approved waterway area are not required for _________________________.
Urinals
Showers in all buildings shall be provided with individual control valves of the _____________________.
Pressure balance type and the thermostatic mixing valve type
The clear space in front of any water closet or bidet shall not be lass than ___________________.
24 inches